Basic Technical Parameters - Roof Mounted Packaged Unit for Double Decker Coaches
| Sr.No. | Parameters |
|
| Electrical Requirement | ||
| 1 | Power Supply | 3 Phase, 415 V ± 5%, 50 Hz ± 3% |
| 2 | Power Consumption | 19 kW |
| Capacity |
||
| 1 | Cooling Capacity | 35.2 kW/10 Tr |
| 2 | Heating Capacity | N/A |
| Constructional Requirement |
||
| 1 | Design to Ambient | 50°C |
| 2 | Max Operating Temperature | 57°C |
| 3 | Dimension (LxWxH) | 2200x2200x550 mm |
| 4 | Material for Housing | SS 304 grade S2 Confirming to IS:6911 |
| 5 | Noise Level(Inside the Coach) | 60dB as per UIC 553 |
| 6 | Controller | Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0139-(Rev.1)-2009 |
| 7 | Refrigrant | R-407C |
| 8 | Weight | 730 kg |
| Service condition |
||
| 1 | Ambient | -4 to 57°C |
| 2 | Max. Temp. inside coach Under Sun | 70°C |
| 3 | Train Speed | 200 Km/h |
| 4 | Relative Humidity | Maximum Up to 100% |
| 5 | Atmosphere | Extremly dusty & desert weather |
| 6 | Shock & Vibration Srandard | IEC 61373 |