Train 18 Saloon HVAC – 8 Tons

Train 18 Saloon HVAC – 8 Tons

Basic Technical Parameters - Train 18 Saloon HVAC

Sr.No.

Parameters

Electrical Requirement
1Power Supply
3 Phase, 415 V ±10%, 50 Hz ±2.5%
2Power Consumption
18.5 kVA
Capacity
1Cooling Capacity
28.1 kW/8 Tr
2Heating Capacity
10.0 kW
Constructional Requirement
1Design to Ambient (Cooling)
50°C
2Max Operating Temperature
55°C
3Dimension (LxWxH)
2600x2500x480 mm
4Material for Housing
Aluminium with Powder Coating
5Noise Level(Inside the Coach)
65 dB as per EN 14750
6Controller
Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/EMU/0196 - 2019 (Rev.0)
7Refrigrant
R-407C
8Weight
585 kg
Service condition
1Ambient
-10 to 55°C
2Max. Temp. inside coach Under Sun
70°C
3Design Speed / Operational Speed
200 Km/h / 160 Km/h
4Relative Humidity
Up to 100%
5Atmosphere
Extremly dusty & desert weather
6Shock & Vibration Srandard
IEC 61373