Basic Technical Parameters - Train 18 Saloon HVAC
| Sr.No. | Parameters |
|
| Electrical Requirement | ||
| 1 | Power Supply | 3 Phase, 415 V ±10%, 50 Hz ±2.5% |
| 2 | Power Consumption | 18.5 kVA |
| Capacity |
||
| 1 | Cooling Capacity | 28.1 kW/8 Tr |
| 2 | Heating Capacity | 10.0 kW |
| Constructional Requirement |
||
| 1 | Design to Ambient (Cooling) | 50°C |
| 2 | Max Operating Temperature | 55°C |
| 3 | Dimension (LxWxH) | 2600x2500x480 mm |
| 4 | Material for Housing | Aluminium with Powder Coating |
| 5 | Noise Level(Inside the Coach) | 65 dB as per EN 14750 |
| 6 | Controller | Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/EMU/0196 - 2019 (Rev.0) |
| 7 | Refrigrant | R-407C |
| 8 | Weight | 585 kg |
| Service condition |
||
| 1 | Ambient | -10 to 55°C |
| 2 | Max. Temp. inside coach Under Sun | 70°C |
| 3 | Design Speed / Operational Speed | 200 Km/h / 160 Km/h |
| 4 | Relative Humidity | Up to 100% |
| 5 | Atmosphere | Extremly dusty & desert weather |
| 6 | Shock & Vibration Srandard | IEC 61373 |