Basic Technical Parameters -Roof Mounted Heating Unit for Electric Locomotives Cab
Sr.No. | Parameters |
|
Electrical Requirement | ||
1 | Power Supply | 3 Phase, 415 V ±10%, 50 Hz ±2.5% |
2 | Power Consumption | 2.5 kW |
Capacity | ||
1 | Cooling Capacity | N/A |
2 | Heating Capacity | 2.0 kW |
Constructional Requirement | ||
1 | Design to Ambient (Heating) | -10°C |
2 | Max Operating Temperature | 20°C |
3 | Dimension (LxWxH) | 952x890x301 mm |
4 | Material for Housing | SS 304 grade S2 Confirming to IS:6911 |
5 | Noise Level(Inside the Coach) | 65 dB |
6 | Controller | Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0020-(latest) |
7 | Refrigrant | N/A |
8 | Weight | 55 kg |
Service condition | ||
1 | Ambient | -10 to 20°C |
2 | Max. Roof Temp. | 30°C |
3 | Train Speed | 120 Km/h |
4 | Relative Humidity | Up to 100% during rainy season |
5 | Atmosphere | Very dusty atmosphare with dust of composite brake block shoe. |
6 | Shock & Vibration Srandard | IEC 60077 / IEC:60571 |