Basic Technical Parameters -Driver's CAB AC For MRVC
| Sr.No. | Parameters |
|
| Electrical Requirement | ||
| 1 | Power Supply | 3 Phase, 415 V ±10%, 50 Hz ±2.5% |
| 2 | Power Consumption | 4.5 kW |
| Capacity |
||
| 1 | Cooling Capacity | 7 kW/2 Tr |
| 2 | Heating Capacity | 2.0 kW |
| Constructional Requirement |
||
| 1 | Design to Ambient (Cooling) | 50°C |
| 2 | Max Operating Temperature | 55°C |
| 3 | Dimension (LxWxH) | 1132x1052x456 mm |
| 4 | Material for Housing | SS 304 grade S2 Confirming to IS:6911 |
| 5 | Noise Level(Inside the Coach) | 65 dB |
| 6 | Controller | Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0020-(latest) |
| 7 | Refrigrant | R-407C |
| 8 | Weight | 187.5 kg |
| Service condition |
||
| 1 | Ambient | -4 to 50°C |
| 2 | Max. Roof Temp. | 70°C |
| 3 | Train Speed | 160 Km/h |
| 4 | Relative Humidity | Up to 100% during rainy season |
| 5 | Atmosphere | Very dusty atmosphare with dust of composite brake block shoe. |
| 6 | Shock & Vibration Srandard | IEC 60077 / IEC:60571 |