Basic Technical Parameters -Roof Mounted Heating Unit for Electric Locomotives Cab

Sr.No.

Parameters

Electrical Requirement
1Power Supply3 Phase, 415 V ±10%, 50 Hz ±2.5%
2Power Consumption2.5 kW
Capacity
1Cooling CapacityN/A
2Heating Capacity2.0 kW
Constructional Requirement
1Design to Ambient (Heating)-10°C
2Max Operating Temperature
20°C
3Dimension (LxWxH)
952x890x301 mm
4Material for Housing
SS 304 grade S2 Confirming to IS:6911
5Noise Level(Inside the Coach)
65 dB
6Controller
Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0020-(latest)
7Refrigrant
N/A
8Weight
55 kg
Service condition
1Ambient
-10 to 20°C
2Max. Roof Temp.
30°C
3Train Speed
120 Km/h
4Relative Humidity
Up to 100% during rainy season
5Atmosphere
Very dusty atmosphare with dust of composite brake block shoe.
6Shock & Vibration Srandard
IEC 60077 / IEC:60571