HVAC -Convn. Coaches of IR – 24.6kW / 7TR

HVAC -Convn. Coaches of IR – 24.6kW / 7TR

Basic Technical Parameters - Roof Mounted Packaged Unit for Conventional Type Coaches

Sr.No.

Parameters

Electrical Requirement
1Power Supply
3 Phase, 415 V ±10%, 50 Hz ±2.5%
2Power Consumption
13 kW (max)
Capacity
1Cooling Capacity
24..6 kW/7 Tr
2Heating Capacity
6.0 kW
Constructional Requirement
1Design to Ambient
50°C
2Max Operating Temperature
57°C
3Dimension (LxWxH)
2200x2100x600 mm
4Material for Housing
SS 304 grade S2 Confirming to IS:6911
5Noise Level(Inside the Coach)
65dB
6Controller
Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0020-(letest)
7Refrigrant
R-407C
8Weight
630 kg
Service condition
1Ambient
-4 to 57°C
2Max. Temp. inside coach Under Sun
70°C
3Train Speed
200 Km/h
4Relative Humidity
Maximum Up to 100%
5Atmosphere
Extremly dusty & desert weather
6Shock & Vibration Srandard
IEC 77