HVAC -Double Decker Coaches – 35.2kW / 10TR

HVAC -Double Decker Coaches – 35.2kW / 10TR

Basic Technical Parameters - Roof Mounted Packaged Unit for Double Decker Coaches

Sr.No.

Parameters

Electrical Requirement
1Power Supply
3 Phase, 415 V ± 5%, 50 Hz ± 3%
2Power Consumption
19 kW
Capacity
1Cooling Capacity
35.2 kW/10 Tr
2Heating Capacity
N/A
Constructional Requirement
1Design to Ambient
50°C
2Max Operating Temperature
57°C
3Dimension (LxWxH)
2200x2200x550 mm
4Material for Housing
SS 304 grade S2 Confirming to IS:6911
5Noise Level(Inside the Coach)
60dB as per UIC 553
6Controller
Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0139-(Rev.1)-2009
7Refrigrant
R-407C
8Weight
730 kg
Service condition
1Ambient
-4 to 57°C
2Max. Temp. inside coach Under Sun
70°C
3Train Speed
200 Km/h
4Relative Humidity
Maximum Up to 100%
5Atmosphere
Extremly dusty & desert weather
6Shock & Vibration Srandard
IEC 61373