HVAC -EMU Coaches - 52kW / 15TR

HVAC -EMU Coaches – 52kW / 15TR

Basic Technical Parameters - Roof Mounted Packaged Unit for EMU Coaches

Sr.No.

Parameters

Electrical Requirement
1Power Supply
3 Phase, 415 V ± 5%, 50 Hz ± 3%
2Power Consumption
21 kW
Capacity
1Cooling Capacity
52.5 kW/15 Tr
2Heating Capacity
N/A
Constructional Requirement
1Design to Ambient
38°C
2Max Operating Temperature
48°C
3Dimension (LxWxH)
3000x2135x405 mm
4Material for Housing
SS 304 grade S2 Confirming to IS:6911
5Noise Level(Inside the Coach)
70dB from 1 meter distance
6Controller
Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0139-(Rev.1)-2009
7Refrigrant
R-407C
8Weight
930 kg
Service condition
1Ambient
40°C
2Max. Temp. inside coach Under Sun
70°C
3Train Speed
120 Km/h
4Relative Humidity
Maximum Up to 98%
5Atmosphere
Extremly dusty & desert weather
6Shock & Vibration Srandard
IEC 61373