Basic Technical Parameters - Roof Mounted Packaged Unit for Vande Bharat Sleeper Coaches
Sr.No. | Parameters |
|
Electrical Requirement | ||
1 | Power Supply | 3 Phase, 415 V ± 5%, 50 Hz ± 3% |
2 | Power Consumption | 13.5 kW |
Capacity | ||
1 | Cooling Capacity | 28.2 kW/8 Tr (With Interlaced Evaporator Coil) |
2 | Heating Capacity | 9 kW (With reverse cycle/ Heat pump mechanism) |
Constructional Requirement | ||
1 | Design to Ambient | 50°C |
2 | Max Operating Temperature | 55°C |
3 | Dimension (LxWxH) | 2565x2154x545 mm |
4 | Material for Housing | AL5083 H111 |
5 | Noise Level(Inside the Coach) | 70dB from 1 meter distance |
6 | Controller | Microprocessor Controller as per RDSO Spec. No.: RDSO/PE/SPEC/AC/0139-(Rev.1)-2009 |
7 | Refrigrant | R-407C |
8 | Weight | 650 kg |
Service condition | ||
1 | Ambient | 50°C |
2 | Max. Temp. inside coach Under Sun | 70°C |
3 | Train Speed | 200 Km/h |
4 | Relative Humidity | Maximum Up to 98% |
5 | Atmosphere | Extremly dusty & desert weather |
6 | Shock & Vibration Srandard | IEC 61373 |