Panel- LHB Hot Buffet Coaches EDTS 134

Panel- LHB Hot Buffet Coaches EDTS 134

Basic Technical Parameters - Switch Board Cabinet LHB Type Hot Buffet Coaches EDTS 134

Sr.No.

Parameters

Electrical Requirement
1Max. Load(Capacity)125 A (max)
2Power Supply
3 Phase, 750 Volts, 50 Hz
Constructional Requirement
1Dimension Main Panel (HxWxD)
1850x1280x1040 mm
2Material for Housing
CRCA steel confirming to IS:513-1994
3Fastners
Zinc plated Confirming to IS:1573-86 & IS:1364-1992.
4Poweder coating Colour
Siemens Gray
Operating & Service condition
1Ambient
5 to 55 deg C
2Train Speed
160 Km/h
3Relative Humidity
Maximum Up to 98%
4Atmosphere
Extremly dusty & desert weather