Basic Technical Parameters - Switch Board Cabinet for LHB Type AC EOG Coaches 184
| Sr.No. | Parameters |
|
| Electrical Requirement | ||
| 1 | Max. Load(Capacity) | 125 A (max) |
| 2 | Power Supply | 3 Phase, 750 Volts, 50 Hz |
| Constructional Requirement |
||
| 1 | Dimension (HxWxD) | 1850x1283x940 mm |
| 2 | Material for Housing | CRCA steel confirming to IS:513-1994 |
| 3 | Fasteners | Zinc plated Confirming to IS:1573-86 & IS:1364-1992. |
| 4 | Powder coating thickness | Minimum 60 microns |
| Operating & Service condition |
||
| 1 | Ambient | -10 to 55 deg C |
| 2 | Temp. Under Sun inside stable Coach | 70 deg C |
| 3 | Train Speed | 200 Km/h |
| 4 | Relative Humidity | Maximum Up to 98% |
| 5 | Atmosphere | Extremly dusty & desert weather |
| 6 | Shock & Vibration Standard | IEC 61373 - 2010 |