Pressurised Flushing System

Pressurised Flushing System

Basic Technical Parameters -Pressurised Flushing System for LHB Coaches with Controller

Sr.No.

Parameters

Basic Parameters
1Pressure Range
Between 2 kg/cm² to 3 kg/cm²
2Duty Cycle
150 Times per day
Controller Parameters
1Dimension (LxWxH)
67x73x100 mm
2Number of Digital Inputs
1
3Number of Analog inputs
0
4Number of outputs
1
5Kind of output
Digital (Relay)
6The programming method
ISP
7IP rating
IP52
8Supply voltage
110AC/DC ±30%
9Power Consumption
1.2 W
10Housing Material
GI with powder coating
11Display/Indicators
2 LED Indicators
12Communication
RS 485
13Data Logging
Yes (Can download via USB)
Operating & Service condition

1Ambient
-4 to +55°C
2Relative Humidity
Maximum Up to 100%
3Atmosphere
Extremely dusty & desert weather